You prevent pressure drops in a temporary compressed air system by correctly sizing the compressor and pipework for peak demand, minimising connection lengths, using adequately sized hoses and fittings, and placing air receivers strategically to buffer demand surges. The most common failures come from undersized connections and poorly planned distribution layouts rather than from the compressor itself. The sections below work through each contributing factor in detail.
What causes pressure drops in a temporary compressed air system?
Pressure drops in a temporary compressed air system occur when resistance in the distribution network consumes pressure before it reaches the end-use equipment. The main contributors are pipe or hose diameter that is too small for the required flow, excessive connection length, sharp bends and poorly matched fittings, high airflow demand relative to supply capacity, and components such as filters or dryers that are partially blocked or undersized.
Temporary installations introduce specific risks that permanent systems do not always face. Flexible hoses, quick-connect couplings, and improvised routing add friction losses that are easy to underestimate at the planning stage. Each additional elbow, reducer, or coupling represents a localised restriction. When several of these stack up across a long temporary distribution run, the cumulative loss can be significant enough to cause tools and processes to underperform even though the compressor itself is delivering the correct discharge pressure.
Airflow demand is equally important. If peak consumption across a site exceeds the compressor’s rated free-air delivery, the system pressure will fall regardless of how well the pipework is sized. In practice, this often happens during shift start-up, when multiple pieces of equipment are activated simultaneously. A well-designed temporary system accounts for this coincident demand rather than only the average load.
Need Reliable Oil-Free Compressed Air?
Our experts help you find the right compressed air rental solution for your industrial needs.
How do you size a temporary compressor correctly to avoid pressure loss?
To avoid pressure loss, size the temporary compressor to deliver enough free-air volume at the required working pressure to meet peak simultaneous demand, with a margin for leakage and start-up surges. Undersizing the compressor is the single most direct cause of system-wide pressure drop, because no amount of good pipework design can compensate for insufficient supply capacity.
Start by listing every piece of equipment that will run concurrently and summing its air consumption at the required working pressure. Add an allowance for distribution leakage, which in temporary systems tends to be higher than in permanent installations due to the number of mechanical connections. A reasonable working margin on top of that calculated figure ensures the compressor operates in a stable part of its performance curve rather than at its limits.
Discharge pressure also matters. A compressor rated at a given flow must be set to deliver pressure high enough to overcome distribution losses and still arrive at the point of use at the minimum acceptable working pressure. If the process requires 7 bar at the machine, and the distribution system loses 0.5 bar across hoses and fittings, the compressor needs to deliver at least 7.5 bar at its outlet. Failing to account for this margin is a common source of pressure complaints that are incorrectly attributed to compressor performance.
For large industrial applications, RTC Group’s oil-free compressor rental fleet covers a wide range of flow and pressure combinations, and the company’s engineers assess site-specific demand before recommending a configuration.
What pipe diameter and hose specifications prevent pressure drops?
Preventing pressure drops through pipework requires selecting hose and pipe diameters large enough to keep air velocity within acceptable limits at the maximum expected flow rate. As a general principle, larger diameters reduce velocity and therefore reduce friction losses along the length of the run. Undersized hoses are one of the most frequent causes of avoidable pressure loss in temporary compressed air systems.
For temporary installations, the hose internal diameter must be matched to the flow rate, not simply to the compressor’s outlet connection size. A compressor with a DN80 outlet connected to a long run of smaller-diameter hose will lose pressure across that hose even if the compressor is performing correctly. The total equivalent length of the run, including bends, couplings, and any reducers, determines the actual friction loss.
Camlock and flanged hose connections used in temporary systems should be confirmed for pressure rating, temperature compatibility, and coupling compatibility before the system goes live. Where the distribution run is long, it is worth calculating the pressure drop across the hose at peak flow and verifying that the residual pressure at the far end still meets process requirements. If it does not, either the hose diameter must increase or the compressor outlet pressure must be raised to compensate.
Keep connection counts as low as possible. Every coupling, valve, and fitting introduces a minor restriction. In a short system these are negligible, but in a temporary installation with many interconnections, they accumulate into a measurable loss.
How does air receiver placement affect pressure stability in temporary setups?
Air receiver placement directly affects pressure stability in a temporary compressed air system by providing a local buffer that absorbs demand peaks and smooths out the pressure fluctuations that occur when consumption briefly exceeds supply. A receiver positioned close to the point of highest demand allows that equipment to draw from stored volume during surges without immediately pulling down system pressure.
In a temporary setup, the most effective placement is downstream of the dryer and as close as practically possible to the main consumption point. This arrangement means the receiver is always holding treated, dry air at working pressure, ready to release it instantly when demand spikes. A receiver positioned only at the compressor end of a long distribution run provides less benefit at the point of use, because the hose between the receiver and the equipment still introduces a restriction during high-demand events.
Receiver volume should be proportional to the variability of demand. Processes with steady, continuous consumption need less receiver volume than those with intermittent or pulsed demand, where the compressor cannot respond quickly enough to prevent short pressure dips. For temporary installations serving multiple intermittent consumers, using more than one receiver at different points in the distribution network often delivers better pressure stability than a single large vessel at the compressor.
RTC Group’s rental fleet includes compressed-air receivers in multiple sizes, allowing the right buffer volume to be matched to the specific installation rather than defaulting to a single standard vessel. Details on available accessories and receivers are listed on the equipment page.
Should you use a desiccant or refrigerant dryer in a temporary compressed air system?
The choice between a desiccant and a refrigerant dryer in a temporary compressed air system depends on the required pressure dew point and the ambient conditions at the installation site. For most standard industrial applications where the distribution pipework is not exposed to near-freezing temperatures and the process tolerates moderate moisture levels, a refrigerant dryer is sufficient and operationally simpler. For moisture-sensitive processes or outdoor installations in cold climates, a desiccant dryer is the correct choice.
Refrigerant dryers work by cooling the compressed air to condense and drain moisture, typically achieving a pressure dew point around 3 to 5 degrees Celsius under standard conditions. This is adequate for most indoor industrial applications where pipework remains above freezing and the end-use equipment can tolerate some residual moisture.
Desiccant dryers use an absorbent medium to achieve significantly lower pressure dew points, making them appropriate when compressed air must pass through outdoor pipework in winter conditions, when the process is moisture-sensitive, or when the application demands very dry air as a quality requirement. The trade-off is higher energy consumption and greater complexity in a temporary installation.
It is also worth noting that the dryer itself can contribute to pressure drop if it is undersized for the actual flow rate or if its internals are partially saturated or blocked. Always confirm that the dryer’s rated capacity at the operating pressure matches or exceeds the compressor’s output at peak demand. An undersized dryer in a temporary system can cause both moisture problems and unexpected pressure loss simultaneously.
How do you test a temporary compressed air system for pressure integrity before going live?
Before commissioning a temporary compressed air system, test it for pressure integrity by pressurising the distribution network to working pressure with all end-use equipment isolated, then monitoring for pressure decay over a defined period. Any measurable drop indicates leakage at connections, couplings, or fittings that must be located and corrected before production begins.
The practical steps for a pre-commissioning pressure check are straightforward:
- Isolate all end-use equipment and close all outlet valves.
- Pressurise the distribution network to the intended working pressure using the temporary compressor or a separate test supply.
- Shut off the supply and monitor the system pressure for a minimum of 15 to 30 minutes.
- Locate any drop in pressure using an acoustic leak detector or soapy water applied to each connection point.
- Repair all identified leaks, re-pressurise, and repeat the test until pressure holds stable.
Beyond leak testing, verify that the pressure at the far end of the distribution run matches expectations under simulated load. This means opening representative end-use points one at a time, measuring the pressure at each, and confirming that the difference between the compressor outlet pressure and the point-of-use pressure stays within the design allowance. If the measured drop exceeds the calculated figure, recheck hose diameters, coupling conditions, and receiver placement before proceeding.
For critical industrial installations where downtime carries serious production consequences, a structured pre-commissioning test conducted with the installation team present is not optional. RTC Group manages installation and start-up as part of its temporary compressed air service, which includes verifying system performance before handing over to the client. If you are planning a temporary installation and want to discuss the configuration in advance, the contact page connects you directly with a specialist.